Cryogenic Particle Detection


Book Description

The development of cryogenic devices for particle detection has reached a stage at which many interesting applications are conceivable and already have been demonstrated. The book provides a comprehensive review of the field of cryogenic particle detection. It introduces the different detection techniques and gives an overview of the important areas in which these detectors are successfully applied.




Superconducting and Low-Temperature Particle Detectors


Book Description

As demonstrated by the contributions in this volume, the domain of superconducting and low-temperature devices is in a rapidly expanding phase. Interactions between materials sciences, low-temperature physics, astrophysics, nuclear and particle physics have provided the incentive for new experiments, which could ultimately record such rare interactions as double beta decay, neutrino scattering, or collisions of the elusive dark matter halo particles. The theoretical and experimental improvements achieved during the last year have been impressive. Detection of 60 keV resolution with a non-zero spin material as a target seems therefore realizable in the near future. Similarly, impressive achievements on ballistic phonons detection and superheated superconducting detectors have been presented, together with reliable techniques for developing ultra low noise electronics required by these ambitious experiments. Apart from the contributions presented during the symposium, the two original papers by Niinikoski proposing the use of bolometers as particle detectors have been included in this volume. These papers, despite their current interest, have never been published before. The comprehensive style of the papers will appeal to specialists and non-specialists alike, in particular solid-state physicists will find the volume of considerable interest, as the field of materials research continues to benefit from the type of work presented here.













Detectors for Particles and Radiation


Book Description

Competent experts provide a summary of the enormous progress achieved in the development of new detection methods of charged and neutral particles, and photons. These achievements were initiated by the advent of new particle colliders, e.g. the LHC at CERN but also by non-accelerator experiments. The present 2nd part of the handbook is devoted to the integration of detectors in large experiments, detectors for special applications, as well as the application of detectors in other fields like e.g. medicine, biology, applied physics and industry.







Transition-edge Sensor with Enhanced Electrothermal Feedback for Cryogenic Particle Detection


Book Description

A superconducting transition-edge sensor with an electrothermal-feedback circuit, a heat sink thermally coupled thereto, a bias-feedback circuit electrically coupled with the electrothermal feedback circuit, and a current sensor electrically coupled with the bias-feedback circuit and inductively coupled with the electrothermal-feedback circuit.




The Cryogenic Dark Matter Search


Book Description

The Cryogenic Dark Matter Search (CDMS) is searching for Weakly Interacting Massive Particles (WIMPs) with cryogenic particle detectors. These detectors have the ability to discriminate between nuclear recoil candidate and electron recoil background events by collecting both phonon and ionization energy from recoils in the detector crystals. The CDMS-II experiment has completed analysis of the first data runs with 30 semiconductor detectors at the Soudan Underground Laboratory, resulting in a world leading WIMP-nucleon spin-independent cross section limit for WIMP masses above 44 GeV/c2. As CDMS aims to achieve greater WIMP sensitivity, it is necessary to increase the detector mass and discrimination between signal and background events. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices has shown that hydrogen passivation of the amorphous silicon blocking layer worsens surface trapping. Additional data has shown that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors causes a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and in situ at the experimental site have provided methods to optimize the neutralization process and monitor running conditions to maintain full ionization collection. This work details my contribution to the 5-tower data taking, monitoring, and analysis effort as well as the SuperCDMS detector development with the focus on monitoring and improving ionization collection in the detectors.