Performance Evaluation of a Real-time Aerosol Monitor


Book Description

The Bureau of Mines laboratory tested the response of a commercially available real-time aerosol monitor (GCA RAM-I) to various dusts. Monitor measurements were recorded, averaged, and compared with simultaneous gravimetric measurements of each test dust. Tests usually lasted several hours. The test dusts of various particle size distributions used included coal, limestone, and a commercially available test dust. For each particular dust, the monitor response was linear and correlated well with mass concentration over the range of about 0.5 to 10 mg/ma3 The monitor can estimate a 2.0-mg/m3 respirable coal dust concentration within as little as ± 6 pet with 95 pet confidence. The monitor must, however, be calibrated with the dust to be measured because the instrument response is affected by the type of dust particle. The average monitor response to a mass concentration of coal dust was approximately twice the average monitor response to the same mass concentration of limestone dust.







11th US/North American Mine Ventilation Symposium 2006


Book Description

This volume is the eleventh in a series which documents the technical papers of the mine ventilation symposium, which was initiated in 1982 by the Underground Ventilation Committee of the Society for Mining, Metallurgy, and Exploration, Inc. In more recent years, the event has expanded to include all of North America and is known as the US/North Am