Cone-beam X-ray Phase Contrast Tomography of Biological Samples


Book Description

Three-dimensional information of entire objects can be obtained by the remarkable technique of computed tomography (CT). In combination with phase sensitive X-ray imaging high contrast for soft tissue structures can be achieved as opposed to CT based on classical radiography. In this work biological samples ranging from micrometer sized single cells over multi-cellular nerve tissue to entire millimeter sized organs are investigated by use of cone-beam propagationbased X-ray phase contrast. Optimization with respect to contrast, resolution and field of view is achieved by addressing instrumentation, sample preparation and phase reconstruction techniques. By using laboratory sources functional soft tissue within the bony capsule of mouse cochleae is visualized in 3D with unprecedented image quality. At synchrotron storage rings the technique reveals more than 1000 axons running in parallel within a mouse nerve and enables doseefficient three-dimensional cellular imaging as well as two-dimensional imaging at high resolutions below 50 nm.




Cone-beam x-ray phase-contrast tomography for the observation of single cells in whole organs


Book Description

X-ray imaging enables the nondestructive investigation of interior structures in otherwise opaque samples. In particular the use of computed tomography (CT) allows for arbitrary virtual slices through the object and 3D information about intricate structures can be obtained. However, when it comes to image very small structures like single cells, the classical CT approach is limited by the weak absorption of soft-tissue. The use of phase information, encoded in measureable intensity images by free-space propagation of coherent x-rays, allows a huge increase in contrast, which enables 3D reconstructions at higher resolutions. In this work the application of propagation-based phase-contrast tomography to lung tissue samples is demonstrated in close to in vivo conditions. Reconstructions of the lung structure of whole mice at down to 5 μm resolution are obtained at a selfbuilt CT setup, which is based on a liquid-metal jet x-ray source. To reach even higher resolutions, synchrotron radiation in combination with suitable holographic phase-retrieval algorithms is employed. Due to optimized cone-beam geometry, field of view and resolution can be varied over a wide range of parameters, so that information on different length scales can be achieved, covering several millimeters field of view down to a 3D resolution of 50 nm. Thus, the sub-cellular 3D imaging of single cells embedded in large pieces of tissue is enabled, which paves the way for future biomedical research.




X-Ray Phase-Contrast Tomography


Book Description

X-ray imaging is a corner stone of breast cancer diagnosis. By exploiting the phase shift of X-rays rather than their attenuation, phase-contrast tomography has the potential to dramatically increase the visibility of small and low contrast features, thus leading to better diagnosis. This thesis presents research on the first synchrotron-based project developing a clinical phase-contrast breast computed tomography (CT) setup at Elettra, the Italian Syncrotron Radiation Facility. This book includes a comprehensive theoretical background on propagation-based phase-contrast imaging, exploring and extending the most recent image formation models. Along with theory, many practical implementation and optimization issues, ranging from detector-specific processing to setup geometry, are tackled on the basis of a large number of experimental evidences. Most of the modelling results and data analysis have general validity, being a valuable framework for optimization of phase-contrast setups. Results obtained at synchrotron are also compared with "real world" laboratory sources: both a first-of-its-kind comparison with one of the few hospital breast CT systems and a state-of-the-art implementation of monochromatic phase-contrast micro-tomography with a conventional rotating anode source are presented. On a more general level, this work sheds a light on the importance of synchrotron-based clinical programs, which are key to trigger the long-anticipated transition of phase-contrast imaging from synchrotrons to hospitals.




Nanoscale Photonic Imaging


Book Description

This open access book, edited and authored by a team of world-leading researchers, provides a broad overview of advanced photonic methods for nanoscale visualization, as well as describing a range of fascinating in-depth studies. Introductory chapters cover the most relevant physics and basic methods that young researchers need to master in order to work effectively in the field of nanoscale photonic imaging, from physical first principles, to instrumentation, to mathematical foundations of imaging and data analysis. Subsequent chapters demonstrate how these cutting edge methods are applied to a variety of systems, including complex fluids and biomolecular systems, for visualizing their structure and dynamics, in space and on timescales extending over many orders of magnitude down to the femtosecond range. Progress in nanoscale photonic imaging in Göttingen has been the sum total of more than a decade of work by a wide range of scientists and mathematicians across disciplines, working together in a vibrant collaboration of a kind rarely matched. This volume presents the highlights of their research achievements and serves as a record of the unique and remarkable constellation of contributors, as well as looking ahead at the future prospects in this field. It will serve not only as a useful reference for experienced researchers but also as a valuable point of entry for newcomers.




Biomedical Imaging


Book Description

Covering both physical as well as mathematical and algorithmic foundations, this graduate textbook provides the reader with an introduction into modern biomedical imaging and image processing and reconstruction. These techniques are not only based on advanced instrumentation for image acquisition, but equally on new developments in image processing and reconstruction to extract relevant information from recorded data. To this end, the present book offers a quantitative treatise of radiography, computed tomography, and medical physics. Contents Introduction Digital image processing Essentials of medical x-ray physics Tomography Radiobiology, radiotherapy, and radiation protection Phase contrast radiography Object reconstruction under nonideal conditions




Multi-scale 3D Virtual Histology Via Phase-contrast X-ray Tomography with Synchrotron Radiation


Book Description

To this day, the standard method for investigating biological tissue with cellular resolution is the examination under a light microscope, first denoted as histology by Karl Meyer in 1819. Despite the enormous success and importance of histology, it has two major disadvantages. Firstly, the specimen must be physically cut into thin sections due to the limited penetrating power of optical light, and secondly, additional staining of the specimen is required to achieve sufficient image contrast. Both disadvantages can be overcome by the non-destructive method of propagation-based X-ray phase-contrast tomography. While the mechanism of phase-contrast provides sufficient image contrast to image single cells, a tomographic imaging scheme with penetrating X-rays allows for an undamaged sample by virtually slicing the reconstructed 3D sample volume. In this work, the holotomography setup of the synchrotron endstation „GINIX“ (The Göttingen Instrument for Nanoscale-Imaging with X-Rays) was extended to a multi-scale X-ray phase-contrast tomography setup suitable for 3D virtual histology by adding two acquisition schemes. Compared to the existing setup, the first additional scheme is a propagation-based microtomography setup, which enlarges the reconstructed 3D volumes by a factor of approx. 64 at a fraction of the acquisition time (ca. 2 min). The second additional scheme aims for higher resolutions. To this end, the X-ray waveguide illumination was combined with photon counting detector with a large field of view and a novel phase reconstruction scheme, which is based on iterative farfield phase retrieval without an „empty-beam correction“ in the detector plane.




3d virtual histology of neuronal tissue by propagation-based x-ray phase-contrast tomography


Book Description

Deciphering the three-dimensional (3d) cytoarchitecture of neuronal tissue is an important step towards understanding the connection between tissue function and structure and determining relevant changes in neurodegenerative diseases. The gold standard in pathology is histology, in which the tissue is examined under a light microscope after serial sectioning and subsequent staining. It is an invasive and labor-intensive technique which is prone to artifacts due to the slicing procedure. While it provides excellent results on the 2d slices, the 3d anatomy can only be determined after aligning the individual sections, leading to a non-isotropic resolution within the tissue. X-ray computed tomography (CT) offers a promising alternative due to its potential resolution and large penetration depth which allows for non-invasive imaging of the sample's 3d density distribution. In classical CT, contrast formation is based on absorption of the x-rays as they pass through the sample. However, weakly absorbing samples like soft tissue from the central nervous system give nearly no contrast. By exploiting the much stronger phase shifts for contrast formation, which the sample induces in a (partially) coherent wavefront, it can be substantially increased. During free-space propagation behind the sample, these phase shifts are converted to a measurable intensity image by interference of the disturbed wave fronts. In this thesis, 3d virtual histology is performed by means of propagation-based x-ray phase-contrast tomography on tissue from the central nervous system of humans and mice. A combination of synchrotron-based and laboratory setups is used to visualize the 3d density distribution on varying lengths scales from the whole organ down to single cells. By comparing and optimizing different preparation techniques and phase-retrieval approaches, even sub-cellular resolution can be reached in mm-sized tissue blocks. The development of an automatic cell segmentation workflow provides access to the 3d cellular distribution within the tissue, enabling the quantification of the cellular arrangement and allowing for extensive statistical analysis based on several thousands to millions of cells. This paves the way for biomedical studies aimed at changes in cellular distribution, e.g., in the course of neurodegenerative diseases such as multiple sclerosis, Alzheimer's disease or ischemic stroke.




Coherent X-ray diffractive imaging on the single-cell-level of microbial samples


Book Description

Since its first experimental demonstration in 1999, Coherent X-Ray Diffractive Imaging has become one of the most promising high resolution X-Ray imaging techniques using coherent radiation produced by brilliant synchrotron storage rings. The ability to directly invert diffraction data with the help of advanced algorithms has paved the way for microscopic investigations and wave-field analyses on the spatial scale of nanometres without the need for inefficient imaging lenses. X-Ray phase contrast which is a measure of the electron density is an important contrast mode of soft biological specimens. For the case of many dominant elements of soft biological matter, the electron density can be converted into an effective mass density offering a unique quantitative information channel which may shed light on important questions such as DNA compaction in the bacterial nucleoid through ‚weighing with light‘. In this work X-Ray phase contrast maps have been obtained from different biological samples by exploring different methods. In particular, the techniques Ptychography and Waveguide-Holographic-Imaging have been used to obtain twodimensional and three-dimensional mass density maps on the single-cell-level of freeze-dried cells of the bacteria Deinococcus radiodurans, Bacillus subtilis and Bacillus thuringiensis allowing, for instance, to estimate the dry weight of the bacterial genome in a near native state. On top of this, reciprocal space information from coherent small angle X-Ray scattering (cellular Nano-Diffraction) of the fine structure of the bacterial cells has been recorded in a synergistic manner and has been analysed down to a resolution of about 2.3/nm exceeding current limits of direct imaging approaches. Furthermore, the dynamic range of present detector technology being one of the major limiting factors of ptychographic phasing of farfield diffraction data has been significantly increased. Overcoming this problem for the case of the very intense X-Ray beam produced by Kirkpatrick-Baez mirrors has been explored by using semi-transparent central stops.




Advanced High-Resolution Tomography in Regenerative Medicine


Book Description

This book covers the state-of-the-art research on advanced high-resolution tomography, exploring its role in regenerative medicine. and also explores the 3D interactions between tissues, cells, and biomaterials. Various multidisciplinary paths in regenerative medicine are covered, including X-ray microtomography and its role in regenerative medicine, synchrotron radiation-based microtomography and phase contrast tomography, the challenge of the vascularization of regenerated tissues, lung and cartilage imaging, and more. This is an ideal book for biomedical engineers, biologists, physicists, clinicians, and students who want to pursue their studies in the field of regenerative medicine. This book also: Reviews in detail the algorithms and software used for the 3D exploration of regenerated tissue Covers the latest research on the use of X-ray microtomography for muscle diseases Details applications of synchrotron radiation tomography in orthopedics and dentistry




Advanced x-ray multilayer waveguide optics


Book Description

The aim of this thesis was to design novel waveguide structures, and to analyze them in view of complex phenomena of near-field propagation. For this purpose, experimental far-field measurements were used in combination with finite-difference simulations and phase retrieval methods. Two novel structures have been designed, fabricated and characterized: the waveguide array (WGA), yielding several waveguided beams in transmission, and multi-guide resonate beam couplers (RBCs), tailored to yield two or several reflected beams. Two novel structures have been designed, fabricated and characterized: the WGA, yielding several waveguided beams in transmission, and multi-guide RBCs, tailored to yield two or several reflected beams. The WGA and the multi-guide RBCs are not only distinct in the coupling geometry. A major difference is related to the fact that the WGA principle is based on the separation (non coupling) of the different transmitted wavelets, while the RBC functions are based on a strong coupling of guided radiation in several layers.