Author : Francis M. Humenik
Publisher :
Page : 52 pages
File Size : 42,73 MB
Release : 1973
Category : Aircraft gas-turbines
ISBN :
Book Description
A test program was conducted to evaluate an experimental short-length annular combustor that uses a one-side-entry dilution airflow concept. The combustor design features scoops on the outer liner for controlling the primary- and secondary-zone airflow distribution. Combustor inlet total pressures were limited to 62 N/sq cm (90 psia) with inlet-air temperatures from 590 K (600 F) to 890 K (1150 F). At a diffuser inlet Mach number of 0.25, the exit temperature pattern factor was 0.44 with an average exit temperature of 1436 K (2124 F) and a total pressure loss of 4.3 percent. At a diffuser inlet Mach number of 0.31, the exit temperature pattern factor was reduced to 0.29 with an average exit temperature of 1450 K (2151 F) and a total pressure loss of 6.1 percent. Nominal combustion efficiencies of 100 percent were obtained with the ASTM A-1 fuel. Exhaust gas emissions, smoke, and altitude relight data are included with exit-temperature profiles and distribution patterns.