Book Description
Development of a National Aerospace Plane (NASP), which will fly at hypersonic speeds, require novel cooling techniques to manage the anticipated high heat fluxes on various components. A compact heat exchanger was constructed consisting of 12 parallel, rectangular channels in a flat piece of commercially pure nickel. The channel specimen was radiatively heated on the top side at heat fluxes of up to 77 W/sq cm, insulated on the back side, and cooled with helium gas flowing in the channels at 3.5 to 7.0 MPa and Reynolds numbers of 1400 to 28,000. The measured friction factor was lower than that of the accepted correlation for fully developed turbulent flow, although the uncertainty was high due to uncertainty in the channel height and a high ratio of dynamic pressure to pressure drop. The measured Nusselt number, when modified to account for differences in fluid properties between the wall and the cooling fluid, agreed with past correlations for fully developed turbulent flow in channels. Flow nonuniformity from channel-to-channel was as high as 12 pct above and 19 pct below the mean flow. Olson, D. A. Unspecified Center COOLING; FRICTION FACTOR; HEAT EXCHANGERS; HEAT FLUX; HEAT TRANSFER; HELIUM; TURBULENT FLOW; DUCTED FLOW; DYNAMIC PRESSURE; HYPERSONIC SPEED; NATIONAL AEROSPACE PLANE PROGRAM; NUSSELT NUMBER; REYNOLDS NUMBER...