Installation Restoration Program: Remedial Investigation Report Addendum for IRP Site Number 6. Volume 1. 161st Air Refueling Group Arizona Air National Guard Sky Harbor International Airport Phoenix, Arizona


Book Description

This document is the Remedial Investigation Report Addendum for IRP Site No. 6, Arizona National Guard, 161st Air Refueling Group, Sky Harbor International Airport, Phoenix, Arizona. This is the first volume of a two volume addendum to the Remedial Investigation Report, May 1996. Site 6. POL Facility was investigated under the Installation Restoration Program. Soil and groundwater samples were collected and analyzed. Remedial Action was recommended for both groundwater and soil associated with the site.




Installation Restoration Program: Remedial Investigation Report Addendum for IRP Site Number 6. Volume 2. 161st Air Refueling Group Arizona Air National Guard Sky Harbor International Airport Phoenix, Arizona


Book Description

This document is the Remedial Investigation Report Addendum for IRP Site No. 6, Arizona National Guard, 161st Air Refueling Group, Sky Harbor International Airport, Phoenix, Arizona. This is the first volume of a two volume addendum to the Remedial Investigation Report, May 1996. Site 6. POL Facility was investigated under the Installation Restoration Program. Soil and groundwater samples were collected and analyzed. Remedial Action was recommended for both groundwater and soil associated with the site.







Installation Restoration Program. Final Remedial Investigation Report. Volume I. 120th Fighter Wing, Montana Air National Guard, Great Falls International Airport, Great Falls, Montana


Book Description

A Remedial Investigation was conducted at the Great Falls Air National Guard Base during April, May, and July 1996. During the period four IRP sites were investigated (IRP Sites 1, 6, 7, and 8). The investigation consisted of drilling 14 soil borings and installing 10 monitoring wells. At Sites 1 and 6, no contaminants in the soil or groundwater were found above State and Federal cleanup levels; and a Decision Document to support no further action is recommended. At Sites 7 and 8, no contaminants were found in the soil above State and Federal cleanup levels; and a Decision Document to support no further action with respect to soil contamination is recommended. At Sites 7 and 8, groundwater contamination above State and Federal cleanup levels was detected. The contamination included petroleum hydrocarbons, chlorinated solvents, and dissolved metals. It is recommended that an Engineering Evaluation/Cost Analysis be prepared to evaluate remedial alternatives for the groundwater at Sites 7 and 8.




Installation Restoration Program Final Remedial Investigation Report IRP Sites 8 and 10. 151st Air Refueling Group Utah Air National Guard, Salt Lake City, Utah


Book Description

This report presents the results from a Remedial Investigation (RI) for two sites at the Utah Air National Guard (UANG) Base located in Salt Lake City, Utah. Stone & Webster Engineering Corporation (Stone & Webster) performed the work for the Air National Guard (ANG) Readiness Center under Task No. 2 of Contract No. DAHA9O-94-D-0009. The two sites investigated are identified as Installation Restoration Program (IRP) Site 8, a former underground storage tank (UST) location, and IRP Site 10, an existing petroleum, oil, and lubricants (POL) yard. The RI was conducted as outlined in the Remedial Investigation/Feasibility Study (RI/FS) Work Plan prepared by Stone & Webster and submitted to and approved by the ANG in May 1993. The field work associated with the RI was performed in June, July, and August 1995.




Installation Restoration Program


Book Description