Seismic Behavior Prediction of Concentrically Braced Steel Frames


Book Description

Concentrically braced steel frames (CBFs) are efficient and commonly used steel systems for resisting seismic loads through a complete truss action. In strong earthquake events, multi-storey concentrically braced steel frames (CBFs) are prone to form a storey-collapse mechanism after buckling and yielding of the braces in a storey. This thesis evaluates the seismic performance of steel concentrically braced frames (CBFs) in Abu Dhabi, UAE. The aim of this study is to assess the overall lateral capacity of multi-storey buildings and the associated sequence of formation of plastic hinges using inelastic pushover analysis technique. The time history analysis approach is employed to assess the local and global seismic performance of braced frame structures under various earthquake records representing the potential seismic loading scenarios. In addition, the adequacy of using inelastic pushover analysis as a simplified means to examine the seismic integrity of braced frame structures and to predict the sequence of development of plastic hinges within the system is evaluated. This study shows that under the expected level of Abu Dhabi's seismicity the designed concentrically braced steel frames (CBFs) perform in an excellent manner by suffering of repairable damages with no life safety threatening. This study puts a step forward in the effort of spreading the knowledge of using the concentrically braced steel frames as lateral force resisting system in Abu Dhabi for mid and high rise buildings.










Experimental and Analytical Studies on the Seismic Behavior of Conventional and Hybrid Braced Frames


Book Description

This dissertation summarizes both experimental and analytical studies on the seismic response of conventional steel concentrically braced frame systems of the type widely used in North America, and preliminary studies of an innovative hybrid braced frame system: the Strong-Back System. The research work is part of NEES small group project entitled "International Hybrid Simulation of Tomorrow's Braced Frames." In the experimental phase, a total of four full-scale, one-bay, two-story conventional braced frame specimens with different bracing member section shapes and gusset plate-to-beam connection details were designed and tested at the NEES@Berkeley Laboratory. Three braced frame specimens were tested quasi-statically using the same predefined loading protocol to investigate the inelastic cyclic behavior of code-compliant braced frames at both the global and local level. The last braced frame specimen was nearly identical to one of those tested quasi-statically. However, it was tested using hybrid simulation techniques to examine the sensitivity of inelastic behavior on loading sequence and to relate the behavior observed to different levels of seismic hazard. Computer models of the test specimens were developed using two different computer software programs. In the software framework OpenSees fiber-based line elements were used to simulate global buckling of members and yielding and low-cycle fatigue failure at sections. The LS-DYNA analysis program was also used to model individual struts and the test specimens using shell elements with adaptive meshing and element erosion features. This program provided enhanced ability to simulate section local buckling, strain concentrations and crack development. The numerical results were compared with test results to assess and refine and the ability of the models to predict braced frame behavior. A series of OpenSees numerical cyclic component simulations were then conducted using the validated modeling approach. Two hundred and forty pin-ended struts with square hollow structural section shape were simulated under cyclic loading to examine the effect of width-to-thickness ratios and member slenderness ratios on the deformation capacity and energy dissipation characteristics of brace members. The concept of a hybrid system, consisting of a vertical elastic truss or strong-back, and a braced frame that responds inelastically, is proposed herein to mitigate the tendency of weak-story mechanisms to form in conventional steel braced frames. A simple design strategy about member sizing of the proposed Strong-Back System is provided in this study. To assess the ability of the new Strong-Back System to perform well under seismic loading, a series of inelastic analyses were performed considering three six-story hybrid braced frames having different bracing elements, and three six-story conventional brace frames having different brace configurations. Monotonic and cyclic quasi-static inelastic analyses and inelastic time history analyses were carried out. The braced frame system behavior, bracing member force-displacement hysteresis loops, and system residual drifts were the primary response quantities examined. These indicated that the new hybrid system was able to achieve its design goals. Experimental results show for the same loading history that the braced frame specimen using round hollow structural sections as brace members has the largest deformation capacity among the three types of bracing elements studied. Beams connected to gusset plates at the column formed plastic hinges adjacent to the gusset plate. The gusset plates tend to amplify the rotation demands at these locations and stress concentrations tended to result in early fractures of the plastic hinges that form. To remedy this problem, pinned connection details used in the last two specimens; these proved to prevent failures at these locations under both quasi-static and pseudo-dynamic tests. Failure modes observed near the column to base plate connections in all of the specimens suggest the need for further study. Both OpenSees and LS-DYNA models developed in this study predict the global braced frame behavior with acceptable accuracy. In both models, low-cycle fatigue damage models were needed to achieve an acceptable level of fidelity. Shell element models were able to predict local behavior and the mode of failures with greater but not perfect confidence. OpenSees analysis results show that the proposed hybrid braced frames would perform better than conventional braced frames and that the story deformations are more uniform. Finally, future research targets are briefly discussed at the end of this dissertation.







Towards Earthquake Resistant Design of Concentrically Braced Steel Structures


Book Description

In recent years, there has been a shift in typical steel construction from moment frames to concentrically braced frames for use in regions of high seismic risk in the United States. Given the large increase in popularity, it is surprising to find that large-scale testing of subassemblages or components of special concentric braced frames is sparse, particularly with frames containing conventional buckling braces and modern construction details. Rigorous analytical modeling of structures with proportions and details typical to those used in concentrically braced frames today are also limited. Test validated analytical models are paramount to adequately predict and assess performance of these structures when subjected to severe ground shaking.




Performance-Based Seismic Demand Assessment of Concentrically Braced Steel Frame Buildings


Book Description

The special concentrically steel braced frame (SCBF) system is one of the most effective struc-tural systems to resist lateral forces. Because of its effectiveness and straightforward design, many SCBFs are incorporated in structures throughout the world. However, the highly nonlin-ear behavior associated with buckling and non-ductile fracture of braces reduces the ability of the system to dissipate energy resulting in undesirable modes of behavior. While many studies have investigated the cyclic behavior of individual braces or the behavior of subassemblies, the dynamic demands on the structural system under various seismic hazard levels needs additional study for performance-based earthquake engineering. Archetype buildings of SCBFs and buckling restrained braced frames (BRBFs) were analyzed using the computer program OpenSees (the Open System for Earthquake Engineering Simulation) to improve the understanding of the seismic behavior of braced frame systems, and to assess seismic demands for performance-based design. Numerical models were calibrated using test data determined from testing of conventional buckling braces, buckling restrained braces, and the braced frame specimens. In addition, fiber-based OpenSees models were constructed and compared with results of a sophisticated finite-element model that realistically captured local buckling and local fracture of structural elements. Because the OpenSees models are reasona-bly accurate and efficient, they were chosen to perform set of parametric computer simulations. The seismic demands of the system and structural elements were computed and interpreted for 3-, 6-, and 16-story SCBFs and BRBFs under various hazard levels. The analysis results show large seismic demands for the 3-story SCBF, which may result in unexpected damage of struc-tural and non-structural elements. The median expected probability of a brace buckling at one or more levels in a 3-story SCBF is more than 50% for an earthquake having a 50% probability of exceedance in 50 years (the service-level event). The possible need to replace braces fol-lowing such frequent events due to brace buckling should be considered in performance-based earthquake engineering assessments. In addition, brace fracture in SCBFs is likely for an earthquake having a 2% probability of exceedance in 50 years (the MCE-level event). Analy-ses show that in general, BRBF models had larger drift demands and residual drifts compared to SCBF systems, because of the BRBF's longer fundamental period. However, the tendency to form a weak story in BRBFs is less than that in SCBFs. Evaluation of seismic demand parameters were performed for 2-, 3-, 6-, 12-, and 16-story SCBFs and BRBFs, which demonstrated that short-period braced frame systems, especially SCBFs, had higher probability of collapse than longer-period braced frame systems. Substantially improved response was observed by lowering the response reduction factor of the 2-story SCBF building; this reduced the collapse risk at the hazard level of 2% probability of exceedance in 50 years. For long-period (taller) structures, although the collapse probability was lower compared to the short-period structures, weak story behavior was commonly observed in conventionally designed SCBF. A design parameter related to the ratios of story shear demand and capacity under a pushover analysis is proposed to modify member sizes to reduce weak story behavior efficiently. This is demonstrated for a 16-story SCBF building. Regarding local deformation and force demands, simple methods to estimate out-of-plane buck-ling deformation of braces and column axial force demands are proposed. The investigation of system performance and member behavior provides seismic demands to more accurately assess the socio-economic losses of SCBFs and BRBFs for performance-based earthquake engineering.




Seismic Behavior, Performance and Design of Steel Concentrically Braced Frame Systems


Book Description

This dissertation describes a research program on special concentrically braced frame (SCBF) and buckling-restrained braced frame (BRBF) systems. The study builds upon previous work performed as part of a research program supported by the George E. Brown Network for Earthquake Engineering Simulation (NEES) entitled "International Hybrid Simulation of Tomorrow's Braced Frame." This program was initiated due to practical and experimental evidence that SCBFs were not performing as intended by current seismic design provisions. The current study includes a comprehensive experimental and analytical program which included two first-of-its-kind, two-story, one-bay by one-bay SCBF and BRBFs experiments. The experiments were performed at the University of Minnesota NEES laboratory to take advantage of its ability to apply large-displacement bi-directional loading. The two specimens were configured with braces in two orthogonal bays framing into a ``shared'' column with a floor system designed and constructed to simulate realistic conditions. The first specimen, the SCBF, employed HSS3x3x1/4 braces in a single-story X-configuration with one continuous brace and a pair of spliced braces in the opposing direction. The second test specimen, the BRBF, employed pin-ended, collared BRBs in a single-diagonal configuration. The analytical study consisted of a large suite of finite element simulations aimed at identifying the main parameters that influence the damage at the beam-column-gusset connection region in BRBFs and to make recommendations for the design and detailing of this connection region. This research has resulted in a number of findings including the observation that out-of-plane loading and deformation had little impact on the drift and ductility capacity of the system when compared to planar frame test results. In fact, the drift capacity of the SCBF test frame was only 6% less than that of comparable planar frames while the ductility and cumulative ductility capacities of the BRBF exceeded that of many of the planar BRBF system tests. Based on the experimental and analytical findings, design and detailing recommendations were developed for the connection at the brace splice point in the single-story, X-configured system. Design and detailing recommendations were also made for the corner gusset plate connection region in BRBFs.







STESSA 2000: Behaviour of Steel Structures in Seismic Areas


Book Description

This is a review of developments in the behaviour and design of steel structures in seismic areas. The proceedings look at the analytical and experimental research on the seismic response of steel structures, and cover topics such as global behaviour and codification, design and application.