Thorium Fuel Cycle


Book Description

Provides a critical review of the thorium fuel cycle: potential benefits and challenges in the thorium fuel cycle, mainly based on the latest developments at the front end of the fuel cycle, applying thorium fuel cycle options, and at the back end of the thorium fuel cycle.




Medical Isotope Production Without Highly Enriched Uranium


Book Description

This book is the product of a congressionally mandated study to examine the feasibility of eliminating the use of highly enriched uranium (HEU2) in reactor fuel, reactor targets, and medical isotope production facilities. The book focuses primarily on the use of HEU for the production of the medical isotope molybdenum-99 (Mo-99), whose decay product, technetium-99m3 (Tc-99m), is used in the majority of medical diagnostic imaging procedures in the United States, and secondarily on the use of HEU for research and test reactor fuel. The supply of Mo-99 in the U.S. is likely to be unreliable until newer production sources come online. The reliability of the current supply system is an important medical isotope concern; this book concludes that achieving a cost difference of less than 10 percent in facilities that will need to convert from HEU- to LEU-based Mo-99 production is much less important than is reliability of supply.




Canada Enters the Nuclear Age


Book Description

The nuclear energy company has overseen the production of its own history, focusing on programs at its laboratories in Chalk River, Ontario, and Whiteshell, Manitoba between 1943 and 1985. The 16 scientists who wrote the narrative discuss the organization and operations of the laboratories, nuclear safety and radiation protection, radioisotopes, basic research, developing the CANDU reactor, managing the radioactive wastes, business development, and revenue generation. Canadian card order number: C97-900188-9. Annotation copyrighted by Book News, Inc., Portland, OR




Molybdenum-99 for Medical Imaging


Book Description

The decay product of the medical isotope molybdenum-99 (Mo-99), technetium-99m (Tc-99m), and associated medical isotopes iodine-131 (I-131) and xenon-133 (Xe-133) are used worldwide for medical diagnostic imaging or therapy. The United States consumes about half of the world's supply of Mo-99, but there has been no domestic (i.e., U.S.-based) production of this isotope since the late 1980s. The United States imports Mo-99 for domestic use from Australia, Canada, Europe, and South Africa. Mo-99 and Tc-99m cannot be stockpiled for use because of their short half-lives. Consequently, they must be routinely produced and delivered to medical imaging centers. Almost all Mo-99 for medical use is produced by irradiating highly enriched uranium (HEU) targets in research reactors, several of which are over 50 years old and are approaching the end of their operating lives. Unanticipated and extended shutdowns of some of these old reactors have resulted in severe Mo-99 supply shortages in the United States and other countries. Some of these shortages have disrupted the delivery of medical care. Molybdenum-99 for Medical Imaging examines the production and utilization of Mo-99 and associated medical isotopes, and provides recommendations for medical use.




Nuclear Energy Basic Principles


Book Description

Describes the rationale and vision for the peaceful use of nuclear energy. The publication identifies the basic principles that nuclear energy systems must satisfy to fulfil their promise of meeting growing global energy demands.




Guidelines for Drinking-water Quality


Book Description

This volume describes the methods used in the surveillance of drinking water quality in the light of the special problems of small-community supplies, particularly in developing countries, and outlines the strategies necessary to ensure that surveillance is effective.




The Supply of Medical Isotopes


Book Description

This report explores the main reasons behind the unreliable supply of Technetium-99m (Tc-99m) in health-care systems and policy options to address the issue. Tc-99m is used in 85% of nuclear medicine diagnostic scans performed worldwide – around 30 million patient examinations every year. These scans allow diagnoses of diseases in many parts of the human body, including the skeleton, heart and circulatory system, and the brain. Medical isotopes are subject to radioactive decay and have to be delivered just-in-time through a complex supply chain. However, ageing production facilities and a lack of investment have made the supply of Tc-99m unreliable. This report analyses the use and substitutability of Tc-99m in health care, health-care provider payment mechanisms for scans, and the structure of the supply chain. It concludes that the main reasons for unreliable supply are that production is not economically viable and that the structure of the supply chain prevents producers from charging prices that reflect the full costs of production and supply.




Radiological Characterization of Shut Down Nuclear Reactors for Decommissioning Purposes


Book Description

This report describes and assesses radiological characterization as a precursor to decommissioning. It shows the influence of the radioactive inventory on the planning and strategies of decommissioning and also presents an extensive overview of characterization results on various reactors which have been or are being decommissioned.




Nuclear Engineering


Book Description