Comparison of Tone Mode Measurements for a Forward Swept and Baseline Rotor Fan


Book Description

A forward swept fan, designated the Quite High Speed Fan (QHSF), was tested in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel to investigate its noise reduction relative to a baseline fan of the same aerodynamic performance. The design objective of the QHSF was a 6 dB reduction in Effective Perceived Noise Level relative to the baseline fan at the takeoff condition. The design noise reduction was to be a result of lower levels of multiple pure tone noise due to the forward swept rotor, and lower rotor/stator interaction tone noise from a leaned stator. Although the design 6 dB reduction was observed in far-field measurements, the induct mode measurements revealed the reasons for goals. All of the noise reduction was from the blade passing tone and its harmonics and most of this was unexpectedly from rotor/strut interaction modes. The reason for large differences in rotor/strut noise sources could not be determined with certainty. The reductions in the multiple pure tone noise for the forward swept rotor were not observed. this reduction were not the ones related to the design Heidelberg, Laurence J. Glenn Research Center NASA/TM-2003-212378, E-13953, NAS 1.15:212378, AIAA Paper 2003-3293







Flow Measurements and Multiple Pure Tone Noise from a Forward Swept Fan


Book Description

A forward-swept fan, designated the Quiet High Speed Fan (QHSF), was tested in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel to investigate its noise reduction relative to a baseline fan of the same aerodynamic performance. The objective of the Quiet High Speed Fan was a 6-dB reduction in the Effective Perceived Noise Level relative to the baseline fan at the takeoff condition. The intent of the Quiet High Speed Fan design was to provide both a multiple pure tone noise reduction from the forward sweep of the fan rotor and a rotor-stator interaction blade passing tone noise reduction from a leaned stator. The tunnel noise data indicted that the Quiet High Speed Fan was quieter than the baseline fan for a significant portion of the operating line and was 6 dB quieter near the takeoff condition. Although reductions in the multiple pure tones were observed, the vast majority of the EPNdB reduction was a result of the reduction in the blade passing tone and its harmonics. Laser Doppler Velocimetry (LDV) and shroud unsteady pressure measurement data were obtained upstream of the QHSF and baseline rotors to improve the understanding of the shocks which propagate upstream of the two fans when they are operated at high speeds. The flow phenomena that produce multiple pure tone noise is discussed and compared to measurements of the fan acoustic inlet modes and the far field noise signature of the fan. Weir, Donald S. and Podboy, Gary G. Glenn Research Center NASA/TM-2005-213413, AIAA Paper 2005-1200, E-14931




Unsteady Aerodynamics, Aeroacoustics and Aeroelasticity of Turbomachines


Book Description

This textbook is a collection of technical papers that were presented at the 10th International Symposium on Unsteady Aerodynamics, Aeroacoustics, and Aeroelasticity of Turbomachines held September 8-11, 2003 at Duke University in Durham, North Carolina. The papers represent the latest in state of the art research in the areas of aeroacoustics, aerothermodynamics, computational methods, experimental testing related to flow instabilities, flutter, forced response, multistage, and rotor-stator effects for turbomachinery.










Aerodynamic Performance Measurements for a Forward Swept Low Noise Fan


Book Description

One source of noise in high tip speed turbofan engines, caused by shocks, is called multiple pure tone noise (MPT's). A new fan, called the Quiet High Speed Fan (QHSF), showed reduced noise over the part speed operating range, which includes MPT's. The QHSF showed improved performance in most respects relative to a baseline fan; however, a partspeed instability discovered during testing reduced the operating range below acceptable limits. The measured QHSF adiabatic efficiency on the fixed nozzle acoustic operating line was 85.1 percent and the baseline fan 82.9 percent, a 2.2 percent improvement. The operating line pressure rise at design point rotational speed and mass flow was 1.764 and 1.755 for the QHSF and baseline fan, respectively. Weight flow at design point speed was 98.28 lbm/sec for the QHSF and 97.97 lbm/sec for the baseline fan. The operability margin for the QHSF approached 0 percent at the 75 percent speed operating condition. The baseline fan maintained sufficient margin throughout the operating range as expected. Based on the stage aerodynamic measurements, this concept shows promise for improved performance over current technology if the operability limitations can be solved.Fite, E. BrianGlenn Research CenterAERODYNAMIC CHARACTERISTICS; TURBOFAN ENGINES; FAN BLADES; NOISE GENERATORS; AERODYNAMIC NOISE; ACOUSTIC DELAY LINES; MASS FLOW; VORTICES; TIP SPEED...




AIAA Journal


Book Description




Aerospace America


Book Description