Development of New Whole Building Fault Detection and Diagnosis Techniques for Commissioning Persistence


Book Description

Commercial building owners spent $167 billion for energy in 2006. Building commissioning services have proven to be successful in saving building energy consumption. However, the optimal energy performance obtained by commissioning may subsequently degrade. The persistence of savings is of significant interest. For commissioning persistence, two statistical approaches, Days Exceeding Threshold-Date (DET-Date) method and Days Exceeding Threshold-Outside Air Temperature (DET-Toa) method, are developed to detect abnormal whole building energy consumption, and two approaches called Cosine Similarity method and Euclidean Distance Similarity method are developed to isolate the possible fault reasons. The effectiveness of these approaches is demonstrated and compared through tests in simulation and real buildings. The impacts of the factors including calibrated simulation model accuracy, fault severity, the time of fault occurrence, reference control change magnitude setting, and fault period length are addressed in the sensitivity study. The study shows that the DET-Toa method and the Cosine Similarity method are superior and more useful for the whole building fault detection and diagnosis. The electronic version of this dissertation is accessible from http://hdl.handle.net/1969.1/148190




Automated Diagnostics and Analytics for Buildings


Book Description

With the widespread availability of high-speed, high-capacity microprocessors and microcomputers with high-speed communication ability, and sophisticated energy analytics software, the technology to support deployment of automated diagnostics is now available, and the opportunity to apply automated fault detection and diagnostics to every system and piece of equipment in a facility, as well as for whole buildings, is imminent. The purpose of this book is to share information with a broad audience on the state of automated fault detection and diagnostics for buildings applications, the benefits of those applications, emerging diagnostic technology, examples of field deployments, the relationship to codes and standards, automated diagnostic tools presently available, guidance on how to use automated diagnostics, and related issues.




Data-driven Whole Building Fault Detection and Diagnosis


Book Description

Residential and commercial buildings are responsible for more than 40% of the primary energy consumption in the United States. Energy wastes are estimated to reach 15% to 30% of total energy consumption due to malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilation, Air-conditioning (HVAC) systems and lighting systems in commercial buildings in the U.S. Studies have demonstrated that a large energy saving can be achieved by automated fault detection and diagnosis (AFDD) followed by corrections. Field studies have shown that, AFDD tools can help to reach energy savings by 5-30% from different systems such as HVAC systems, lighting systems, and refrigeration systems. At the same time, the deployment of AFDD tools can also significantly improve indoor air quality, reduce peak demand, and lower pollution. In buildings, many components or equipment are closely coupled in a HVAC system. Because of the coupling, a fault happening in one component might propagate and affect other components or subsystems. In this study, a whole building fault (WBF) is defined as a fault that occurs in one component or equipment but causes fault impacts (abnormalities) on other components and subsystems, or causes significant impacts on energy consumption and/or indoor air quality. Over the past decades, extensive research have been conducted on the development of component AFDD methods and tools. However, whole building AFDD methods, which can detect and diagnose a WBF, have not been well studied. Existing component level AFDD solutions often fail to detect a WBF or generate a high false alarm rate. Isolating a WBF is also very challenging by using component level AFDD solutions. Even with the extensive research, cost-effectiveness and scalability of existing AFDD methods are still not satisfactory. Therefore, the focus of this research is to develop cost-effective and scalable solutions for WBF AFDD. This research attempts to integrate data-driven methods with expert knowledge/rules to overcome the above-mentioned challenges. A suite of WBF AFDD methods have hence been developed, which include: 1) a weather and schedule based pattern matching method and feature based Principal Component Analysis (WPM-FPCA) method for whole building fault detection. The developed WPM-FPCA method successfully overcome the challenges such as the generation of accurate and dynamic baseline and data dimensionality reduction. And 2) a data-driven and expert knowledge/rule based method using both Bayesian Network (BN) and WPM for WBF diagnosis. The developed WPM-BN method includes a two-layer BN structure model and BN parameter model which are either learned from baseline data or developed from expert knowledge. Various WBFs have been artificially implemented in a real demo building. Building operation data which include baseline data, data that contain naturally-occurred faults and artificially implemented faults are collected and analyzed. Using the collected real building data, the developed methods are evaluated. The evaluation demonstrates the efficacy of the developed methods to detect and diagnose a WBF, as well as their implementation cost-effectiveness.




Fault Detection and Diagnosis in Engineering Systems


Book Description

Featuring a model-based approach to fault detection and diagnosis in engineering systems, this book contains up-to-date, practical information on preventing product deterioration, performance degradation and major machinery damage.;College or university bookstores may order five or more copies at a special student price. Price is available upon request.







Metrics and Methods to Assess Building Fault Detection and Diagnosis Tools


Book Description

This paper presents the research methodology and findings related to fault definition, input samples, and evaluation metrics. We discuss these findings in light of key considerations for FDD algorithm performance testing, and conclude with recommendations and suggested areas of future work.




An Open, Cloud-Based Platform for Whole-Building Fault Detection and Diagnostics


Book Description

Small commercial buildings in the U.S. waste an estimated 300 Trillion BTU (approximately $6 billion in energy costs) annually due to faults, but lack cost-effective automated fault detection and diagnosis (AFDD) tools. NREL and GE Global Research are partnering to develop hybrid AFDD algorithms tailored to the unique needs of small commercial buildings (




Model-based Fault Diagnosis in Dynamic Systems Using Identification Techniques


Book Description

Safety in industrial process and production plants is a concern of rising importance but because the control devices which are now exploited to improve the performance of industrial processes include both sophisticated digital system design techniques and complex hardware, there is a higher probability of failure. Control systems must include automatic supervision of closed-loop operation to detect and isolate malfunctions quickly. A promising method for solving this problem is "analytical redundancy", in which residual signals are obtained and an accurate model of the system mimics real process behaviour. If a fault occurs, the residual signal is used to diagnose and isolate the malfunction. This book focuses on model identification oriented to the analytical approach of fault diagnosis and identification covering: choice of model structure; parameter identification; residual generation; and fault diagnosis and isolation. Sample case studies are used to demonstrate the application of these techniques.







Fault-Diagnosis Systems


Book Description

With increasing demands for efficiency and product quality plus progress in the integration of automatic control systems in high-cost mechatronic and safety-critical processes, the field of supervision (or monitoring), fault detection and fault diagnosis plays an important role. The book gives an introduction into advanced methods of fault detection and diagnosis (FDD). After definitions of important terms, it considers the reliability, availability, safety and systems integrity of technical processes. Then fault-detection methods for single signals without models such as limit and trend checking and with harmonic and stochastic models, such as Fourier analysis, correlation and wavelets are treated. This is followed by fault detection with process models using the relationships between signals such as parameter estimation, parity equations, observers and principal component analysis. The treated fault-diagnosis methods include classification methods from Bayes classification to neural networks with decision trees and inference methods from approximate reasoning with fuzzy logic to hybrid fuzzy-neuro systems. Several practical examples for fault detection and diagnosis of DC motor drives, a centrifugal pump, automotive suspension and tire demonstrate applications.