Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring DOENA27323-1


Book Description

Compact maintenance free mechanical cooling systems are being developed to operate large volume germanium detectors for field applications. To accomplish this we are utilizing a newly available generation of Stirling-cycle mechanical coolers to operate the very largest volume germanium detectors with no maintenance. The user will be able to leave these systems unplugged on the shelf until needed. The flip of a switch will bring a system to life in ~ 1 hour for measurements. The maintenance-free operating lifetime of these detector systems will exceed 5 years. These features are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems for Nuclear Explosion Monitoring. The Radionuclide Aerosol Sampler/Analyzer (RASA) will greatly benefit from the availability of such detectors by eliminating the need for liquid nitrogen at RASA sites while still allowing the very largest available germanium detectors to be reliably utilized.







Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring


Book Description

Compact maintenance-free mechanical cooling detector systems are being developed to operate large-volume (approximately 570 cubic cm, approximately 3 kg, 140% or larger) germanium detectors for field applications. These detector systems are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems. The Radionuclide Aerosol Sampler/Analyzer (RASA) nuclear explosion monitoring systems will benefit from the availability of such detector systems by allowing the very largest available germanium detectors to be utilized for the highest sensitivity measurements. To reliably provide such detector systems, three fundamental technical issues are being investigated: temperature, vacuum, and vibration. Two prototype detector systems (RASA 1 and RASA 2) have been developed, fabricated, and tested. The cryostats have been demonstrated to cool very large (slightly greater than 10(+)-cm long and 10-cm diameter) detectors to temperatures as low as 50 K. The vacuum design has been demonstrated to show no measurable degradation over long time periods. The detector systems have been demonstrated to successfully instrument high-purity germanium detectors. Microphonic noise from the vibrating cooler has been completely eliminated in one case, serving as a demonstration of the total detector system viability. Microphonic noise remains the largest technical issue for these detector systems. The third generation, RASA 3, design incorporates mechanical changes to eliminate microphonic noise issues.